7
Input and Output
Output is open collector 12V, 50mA switching negative, for heavier loads a relay
must be used.
The outputs can be Opened, Closed or Pulsed remotely using the Permaconn Atlas
web platform.
Ensure there is a common negative between PM1030 and the device being
switched.
Tamper input does not require an EOL resistor.
All other inputs must be terminated with a 10K resistor.
Defaulting the Permaconn PM1030
Apply Battery or 14.5V DC power for less than two (2) seconds remove power and
then apply power again.
LEDS will all flash together for four (4) seconds to confirm successful default.
DI300 Powered by Panel – PM1030 Powered Independent Supply
RDCCO_2143_E_IN
PM1030 Manual March 2019 v2.2