5
Connecting the DI300
Connecting the Alarm Panel
Always use the original telephone lead supplied with the alarm panel – between the
alarm panel and the DI300.
A four wire connection is required between the alarm panel and the DI-300 module.
Ring & Tip as input and R1 & T1 as the return line.
Always use 611 Tail plugged into the DI300
Connect PSTN in Mode 3.
Unit is supplied as GPRS primary with PSTN back up.
To make the PSTN primary and GPRS back up, the PSTN jumper must be re-
moved from the DI300.
The option of PSTN primary should only be selected after installation and testing
with GPRS as primary.
If PSTN is primary you must test the following:
Trigger the ‘tamper’ input on the Permaconn PM1030 unit. Verify with the monitoring
centre that a tamper was received with the correct CID account number
RDCCO_2143_E_IN