Standards Compliance 

 

In this manual, ‘AS2201.1’ refers to AS/NZS 2201.1:2007, ‘AS2201.5’ refers to AS/
NZS 2201.5:2008 and ‘AS2201’ refers to the current issues of the AS2201 range of 
documents. 

 

In order to achieve compliance with AS2201.5, the terms of the current issue of the 
document ‘Permaconn AS/NZS 2201.5:2008 Compliance Statement’ must be met. 

 

Note that the overall alarm transmission system configuration needs to comply with 
AS2201.1 and AS2201.5. 

 

It is stressed that the supervised premises alarm panel is be installed and maintained in 
order to meet Class (as relevant to the alarm transmission system classification) under 
AS2001.  The logbook required under Clause 6.4 of that Standard is to remain current. 

 

The  monitoring centre is to hold a copy of the documentation required at AS2201.5 
Clause 2.3. 

 

The monitoring centre is to maintain ‘fault and maintenance logs’ in accordance with 
AS 2201.5 Clause 3.9.on. 

 

 

Subject to the Standard Terms and Conditions set out on the Activation Form for this 
unit. 

INSTALLATION MUST BE CARRIED OUT BY SERVICE PERSONNEL ONLY 
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCOR-

RECT TYPE. DISPOSE OF USED BATTERIES. 

For correct operation the unit must be powered with an approved power supply and a 

12V/1.2AH sealed lead acid battery. 

The  unit  must  only  be  operated  with  the  supplied  antenna.  Install  the  Permaconn 

PM1030 in a location that no person[s] is closer than 200 mm to the antenna at all 
times. 

Australian Standard AS2201 requires regular service by qualified and licensed techni-

cians and regular testing. 

The unit must be installed in accordance with this manual and AS2201.1 for proper         
operation.

 

Liability 

Warning       

 

 

 

 

 

 

While every effort has been taken to ensure the accuracy of this document, RDCCO Pty Ltd assumes no 
responsibility or liability for any errors or omissions. RDCCO Pty Ltd reserves the right to make changes 
to this manual due to ongoing development. 

RDCCO_2143_E_IN 

PM1030 Manual March 2019 v2.2  

Содержание PM1030

Страница 1: ...PERMACONN PM1030 Includes DI300 Installation Manual RDCCO Pty Ltd Unit 3 9 11 Stubbs Street Rydalmere NSW 2116 Telephone 02 9352 1777 Web www permaconn com...

Страница 2: ...conn PM1030 7 DI300 Powered by Panel PM1030 Powered Independent Supply 7 PM1030 V2 and DI300 Powered by Panel Transmission Delay Times 8 LED Status Indicators PM1030 9 LED Status Indicators DI300 10 F...

Страница 3: ...to the registered fault recognition time Features of the Permaconn PM1030 Four 4 Inputs and a dedicated box tamper Three 3 Outputs Contact ID interface requires DI300 module RS485 RS232 Interface requ...

Страница 4: ...ogram alarm panel Generate an event from the alarm panel The Online GPOL LED will stay on steady Test all inputs and outputs Carry out all tests on Final Commissioning Check List Never leave site with...

Страница 5: ...he DI300 Connect PSTN in Mode 3 Unit is supplied as GPRS primary with PSTN back up To make the PSTN primary and GPRS back up the PSTN jumper must be re moved from the DI300 The option of PSTN primary...

Страница 6: ...one number Panel must report Contact ID format Panel must be programmed with a Hard ID Disable telephone line monitoring feature from the panel Battery Charging A dedicated 14 5V power supply is requi...

Страница 7: ...30 and the device being switched Tamper input does not require an EOL resistor All other inputs must be terminated with a 10K resistor Defaulting the Permaconn PM1030 Apply Battery or 14 5V DC power f...

Страница 8: ...ered by the alarm panel Transmission Delay Times Tamper input status message are transmitted immediately Message originating from the panel are forwarded immediately Alarm panel interface fail sent if...

Страница 9: ...LED Activity Indication POWER On Indicates battery or 14 5 Volt Power Off Indicates unit is off GSM On Unit not activated or network is not available Blinking 1 sec On 1 sec Off Searching for 3G netwo...

Страница 10: ...es fault with wiring between PM1030 and DI300 Check blue and white wire PSTN On Indicates that there is no line voltage on the incoming telephone from the ex change Off Indicates PSTN line voltage Off...

Страница 11: ...panel Verify with monitoring centre that correct CID account and event received Test alarm panel PSTN communication Remove jumper from DI300 Generate event from alarm panel Verify with monitoring cen...

Страница 12: ...mmunicate Permaconn experienced trouble sending signals do not expect restore 351 0 954 956 Phone Line Fail 352 0 955 956 Dialer Interface Lead Fail Issue with dialer lead between Permaconn unit and t...

Страница 13: ...rface Consult the relevant serial interface specifications Battery Low Fail DCV 11 8 Report delay 10 minute Restore DCV 12 5 Immediate Communications Class As per compliance statement Size 70 x 50 x 2...

Страница 14: ...e with AS 2201 5 Clause 3 9 on Subject to the Standard Terms and Conditions set out on the Activation Form for this unit INSTALLATION MUST BE CARRIED OUT BY SERVICE PERSONNEL ONLY CAUTION RISK OF EXPL...

Страница 15: ...15 NOTES RDCCO_2143_E_IN PM1030 Manual March 2019 v2 2...

Отзывы: