Peritek
6-8
Troubleshooting
Table 6-2
Common CPU board addresses
Fault
Possible Cause
Corrective Action
Control Panel dead -
On/Off switch unlit
No AC power
Check power cord. It may have been
dislodged when installing board.
On/Off Switch lit
No DC power
Check for c5 and +12 volts.
Cannot Boot
Cable(s) dislodged
During installation an unrelated cable
can get dislodged.
Cannot read Peritek
distribution media
Improperly inserted,
damaged, or incorrect
media.
Check insertion and position. Take
care that media is "mounted"
properly. Unix distribution uses TAR
format.
No message on
console terminal or
messages are garbled
Terminal disconnected
or not configured
properly.
Make sure cable between terminal
and computer is plugged into proper
terminal port. Put terminal into Local
mode and verify operation.
System crashes or you
get a "Trap" message
Software not installed
correctly
Check installation procedures. See
Software Release Notes.
No image on Monitor
COAX cables not
connected properly or
monitor is not on.
Check BNC cables, replace if
necessary. Be sure to initialize board
with correct initialization table.
Image is smeared or
doing flip-flops
Sync signals missing or
monitor sync failure.
Make sure monitor accepts sync on
green, that monitor is terminated, and
the hold controls are adjusted
properly. Make sure that R,G,and B
cables do go to R,G and B inputs.
Check initialization parameters.
PX Windows Server is
very slow to start up.
Mouse movement is
fast but windows are
slow to open.
Graphics board to Host
CPU interrupts are not
being serviced.
Check interrupt pass/grant jumpers.
Check operating system for correct
interrupt configuration.
No response to mouse
motion and/or
keyboard entry.
Keyboard or mouse
cable not plugged in. PX
Windows board side
server is crashed.
Check cabling. Reload software.
Содержание VCD-V
Страница 2: ...Peritek ...
Страница 3: ...Peritek ...
Страница 5: ...Peritek ...
Страница 6: ...Peritek ...
Страница 10: ...Peritek ...
Страница 41: ...Peritek 2 10 Installing Your Peritek Graphics Board Figure 2 2 Jumper Locations for the VCT V and VCU V ...
Страница 42: ...Peritek Installing Your Peritek Graphics Board 2 11 Figure 2 3 Jumper Locations for the VCD V ...
Страница 94: ...Peritek Theory of Operation 4 15 Figure 4 1 VCD V Block Diagram ...
Страница 95: ...Peritek 4 16 Theory of Operation Figure 4 2 VCU V Block Diagram ...
Страница 96: ...Peritek Theory of Operation 4 17 Figure 4 3 VCT V Block Diagram ...