![Peri SKYDECK Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/peri/skydeck/skydeck_instructions-for-assembly-and-use_1529937038.webp)
36
12
12
9*
x
y
9
9
L
SPH
L
SPH
≤ 0.20
0.25
≤ 0.40
0.30
≤ 0.70
0.40
≤ 1.15
100
80
60
14
30
58
137
16
26
51
121
18
23
46
108
20
21
41
98
22
19
38
89
24
18
35
82
25
17
33
79
26
16
32
76
28
15
30
71
30
14
28
66
35
12
24
57
40
11
21
50
43
10
20
46
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
A6 Shuttering around columns
Additional Edge Beam SRT-2 150 (9)
required with:
Permissible width of influence of flat Filler Timber SPH,
maximum deformation l/500
For other slab thicknesses, the values
are interpolated linearly.
Take into account the supporting
direction of the formlining.
Fig. A6.10
Fig. A6.09
3 recessed panels
Maximum column dimensions
x = 138 cm, y = 142 cm.
Secure filler plates with nails!
Install Edge Beam SRT-2 150 (9) vertically,
Edge Beam SRT-2 150 (9*) suspended,
Filler Timber SPH 150 (12) horizontally.
(Fig. A6.09, Fig. A6.10)
Table A6.01
Slab thickness
d [m]
Column side
y [m]
no additional SRT
Slab thickness
permissible width of influence Filler Timber SPH flat e
SPH,flat
[cm]
with span L
SPH
[cm]
Table A6.02
SKYDEKC AuV_ex_791458.indb 36
13.12.16 16:56
Содержание SKYDECK
Страница 1: ...SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration Edition 09 2016...
Страница 25: ...23 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Страница 47: ...45 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Страница 87: ...85 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...