AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Function and startup of the Safety Monitor
27
.9.20
13
65
•
Fieldbus interface
1
10.4.1
Diagnostics of release circuits 1-4 via the binary data
If monitor slaves with base a1 and +2 exist, the state of several OSSDs
is transmitted there.
10.5
Switch-off history
The switch-off history, accessible from the menu DIAGNOSTICS->INT MONI-
TOR->LAST DIAGNOSTIC, is intended to make reconstruction of the reason for
switch-off easier for the user. The states of all safety-relevant AS-i slaves and all
devices at the time the state change on the output device (change from green to
another color) are stored.
Monitor base 1 assignment
Data bit
Content
D0
State of output circuit 1
D1
State of message output 1
D2
State of output circuit 2
D3
State of message output 2
Monitor base 2 assignment
Data bit
Content
D0
State of output circuit 3
D1
State of message output 3
D2
State of output circuit 4
D3
State of message output 4
Information!
Available only with AS-i/PROFINET Gateways.