AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
General
27
.09.2
013
11
4.
General
4.1
Product information
This system manual applies to the following Fuchs equipment:
4.1.1
AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
A
rt
icl
e No
.
Ty
p
e
Input
s sa
fe
ty, e
x
pa
ndable
t
o
Out
puts Safe
ty
,
SI
L
3, ca
t.
4
Safety
out
puts,
independe
nt
acc
ording to SI
L
3,
Saf
e
ty
communi
cat
ion
N
u
mbe
r of AS-i ne
tw
orks
,
n
u
m
b
er of AS
-i
Mas
te
r
1 powe
r supply
,
1
gat
ew
a
y for 2
A
S
-i
ne
tw
orks
1
D
iagnostic
and
configuration inter
fa
c
e
2
Program
ming in C
VBG-PN-K30-DMD-S16
Safety,
PROFI-
NET
max.
62 x
2 chan-
nels
4 release
circuits;
2 x relay,
2 x fast
electronic
safe outputs
max.
16
-
2 AS-i
net-
works, 2
AS-i
Masters
no, max.
8A/AS-i
network,
redundant
supply
Ethernet
fieldbus
+ RS 232
no
VBG-PN-K30-D-S16
Safety,
PROFI-
NET
max.
62 x
2 chan-
nels
4 release
circuits;
2 x relay,
2 x fast
electronic
safe outputs
max.
16
-
2 AS-i
net-
works, 1
AS-i
Master
no, max.
8A/AS-i
network,
redundant
supply
Ethernet
fieldbus
+ RS 232
no
VBG-PN-K30-DMD-S16-
EV
Safety,
PROFI-
NET
max.
62 x 2
chan-
nels,
max.
1922
in max.
configu-
ration
4 release
circuits;
2 x relay,
2 x fast
electronic
safe outputs
max.
32,
max.
992 in
max.
confi-
gura-
tion
Safe
Link
2 AS-i
net-
works, 2
AS-i
Masters
no, max.
4A/AS-i
Kreis
Ethernet
fieldbus
+ RS 232
optio-
nal
Power24V
3
Tab. 4-1. Funcion range "AS-i 3.0 PROFINET Gateway with integr. Safety Monitor"
1. power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies:
- "yes, max. 4A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1
power supply).
- "no, max. 8A/AS-i network, redundant supply":
1 power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.
Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to
be maintained and the unaffected AS-i network continues to operate.
"no, max. 8A/AS-i network":
1 power supply per AS-i network
2. Ethernet fi RS 232:
Access to AS-i master and safety monitor via Fuchs proprietary software over Ethernet fieldbus interface
or RS 232 interface and adapter cable.
3. AS-i Power24V capable:
- VBG-PN-K30-DMD-S16-EV device can be operated directly on a 24V (PELV) power supply
- with integrated data coupling coils and adjustable self-resetting fuses for safe use also of powerful 24V power sup-
plies.
Содержание VBG-PN-K30-D-S16
Страница 1: ...AS I 3 0 PROFINET GATEWAY WITH INTEGR SAFETY MONITOR FACTORY AUTOMATION MANUAL...
Страница 41: ...AS i 3 0 PROFINET Gateway with integr Safety Monitor Installation 27 9 2013 41 1 new old 2 3...
Страница 125: ...AS i 3 0 PROFINET Gateway with integr Safety Monitor Appendix Examples 27 9 2013 125...
Страница 126: ...27 9 2013 126 AS i 3 0 PROFINET Gateway with integr Safety Monitor Appendix Examples...
Страница 130: ......