AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Configuration of AS-i/PROFINET Gateways
The cyclical output identifier contains the 4 Safety Monitor bits 1.Y1, 1.Y2, 2.Y1
and 2.Y2. The monitoring element “Monitor input” and the start elements “Monitor
Start-Monitor Input” and “Activation using Monitor Input” access these data. In
contrast, the “Feedback circuit” element always accesses the EDM input.
The bits of the output bytes are ORed with the real and the homonymous hard-
ware inputs of the device.
0
no device flashing red
1
at least one device flash-
ing red
Outputs
byte description
1 byte from the fieldbus
bit 0: 1.Y1
bit 1: 1.Y2
bit 2: 2.Y1
bit 3: 2.Y2
bit 4 ... 7: reserved
2 reserved
Tab. 13-36.
Safety Control Status
Length
description
2 byte I
1 byte O
Safety Ctrl/Status (2 OSSD)
4 byte I
1 byte O
Safety Ctrl/Status (4 OSSD)
6 byte I
2 byte O
Safety Ctrl/Status (6 OSSD)
8 byte I
2 byte O
Safety Ctrl/Status (8 OSSD)
10 byte I
3 byte O
Safety Ctrl/Status (10 OSSD)
12 byte I
3 byte O
Safety Ctrl/Status (12 OSSD)
14 byte I
4 byte O
Safety Ctrl/Status (14 OSSD)
16 byte I
4 byte O
Safety Ctrl/Status (16 OSSD)
Tab. 13-37.
Coding of status bytes
Tab. 13-35.
Содержание VBG-PN-K30-D-S16
Страница 1: ...AS I 3 0 PROFINET GATEWAY WITH INTEGR SAFETY MONITOR FACTORY AUTOMATION MANUAL...
Страница 41: ...AS i 3 0 PROFINET Gateway with integr Safety Monitor Installation 27 9 2013 41 1 new old 2 3...
Страница 125: ...AS i 3 0 PROFINET Gateway with integr Safety Monitor Appendix Examples 27 9 2013 125...
Страница 126: ...27 9 2013 126 AS i 3 0 PROFINET Gateway with integr Safety Monitor Appendix Examples...
Страница 130: ......