AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Electrical connection
27
.9.20
13
53
9.4.2
Electrical connection VBG-PN-K30-DMD-S16-EV
Terminal
Signal / Description
+ASI 1–
Connection to AS-i Circuit 1
+AS-i 2–
Connection to AS-i Circuit 2
ASI +PWR– /
24 V, 0 V
Supply voltage for AS-i Circuits (max. 8 A) /
Power 24
1
supply optional
1.
The gateway is AS-i Power24V capable and can be operated directly on a 24V (PELV) power sup-
ply.
FG
Function ground
+
-
+
-
+
-
+
+ASI 2–
+ASI 1–
+ASI 1–
ASI +PWR– (max. 8A)
/
24V, 0V
+ASI
1
+ASI
2
+ASI
1
+
-
+ASI PWR-
24V 0V
M4
5 mm max!
Function ground
Gateway
Safety Unit
Information!
AS-i Circuit 1 and 2 are both powered from a Fuchs GmbH power supply!
No other power supplies are approved!
Attention!
Earth fault detector sensor without function when using
AS-i Power24
!
Information!
For additional information, please refer to the sections: <AS-i and power supply termi-
nal assignments> and <AS-i Power24V capable>.