To achieve a Protection class of IP65,
• the seal insert must be cooled with cold spray while it is being drilled.
or
• the seal insert must be cooled down to a temperature of -5°C or colder in a freezer,
after which drilling may take place.
or
• The seal insert may be drilled at room temperature so that it is greater in diameter
than the diameter of the cable by approximately 0.7 mm.
The following illustration show a good and a bad drilling job.
Make certain that the drilling process does not produce any grooves.
5.1.2
Mechanical assembly
Straps should be attached to the housing of the connecting circuit to facilitate the as-
sembly of the TCP/IP. These are included with delivery. They can be screwed in place
with the housing using M6x1 screws.
The housing is held in place at the installation location by these straps.
5.2
Electrical connections
5.2.1
Power supply
The power supply for the TCP/IP connecting circuit can be either 24 VDC or 230 VAC.
If the connecting circuit is supplied with 24 VDC, the conductors should be applied to
the distributor terminals through Connector 8 (ST8) (See “Appendix A: Wiring dia-
gram” on page61.).
If the TCP/IP connecting circuit is supplied with 230 VAC, the conductors should be
connected to the power pack by means of Connector 10 (ST10). The power pack gen-
The last method of processing described above is the least accurate.
For all three options, the drilling must be performed with a slow feed at
a drilling speed of 500 rpms.
There is no guarantee that a Protection class rating of IP 65 will be
achieved if drilling is performed without the use of cold spray.
Good drill hole
Bad drill hole