IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
53
10.26 <62> Set outputs
Set/reset the outputs of the Control Interface unit.
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚6‘ (0x36)
Byte 2
‚2‘ (0x32)
Byte 3
NC
Byte 4
NC
Byte 5
NC
Byte 6
NC
Byte 7
Bit 0 = Output 1
Bit 1 = Output 2
Bit 2 = Output 3
Bit 3 = Output 4
Response for processing with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚6‘ (0x36)
Byte 2
‚2‘ (0x32)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1