42
10.15 <47> Delete data carrier
The data carrier is deleted and the content is filled with a deletion sample.
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚7‘ (0x37)
Byte 3
Destination address high byte
Byte 4
Destination address low byte
Byte 5
Number of bytes high
Byte 6
Number of bytes low
Byte 7
Deletion sample
Response for processing with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚7‘ (0x37)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1
Byte 5
Deletion sample