IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
31
10.6
<64> Write data carrier, single write
Write data in data carrier. If no data carrier is present, the appropriate error message
will be sent back.
Command:
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚6‘ (0x36)
Byte 2
‚4‘ (0x34)
Byte 3
Destination address high byte
Byte 4
Destination address low byte
Byte 5
Number of bytes high
Byte 6
Number of bytes low
Byte 7
Data to be written
- „ -
- „ -
- „ -
- „ -
Byte n
- „ -
Response for processing with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚6‘ (0x36)
Byte 2
‚4‘ (0x34)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1
Byte 5
Battery status of data carrier in %