10.10 <44> Control Interface unit -> write to data carrier
Read data from memory of the Control Interface unit and transfer into the data carrier.
If no data carrier is present, the appropriate error message will be sent back.
If a status message is present, the Control Interface unit responds with an error mes-
sage that is described in Section 10.2 on page 27 .
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚4‘ (0x34)
Byte 3
Source/destination address high byte
Byte 4
Source/destination address low byte
Byte 5
Number of bytes high
Byte 6
Number of bytes low
Response for processing with no errors
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚4‘ (0x34)
Byte 3
Status
Byte 4
I1
T1
S2
S1
EC4
EC3
EC2
EC1