The SW1 ... SW4 switches of the MVI-D2-2HRX Control Interface unit must be set as
follows for communication with the RS232/TTL converter:
Table 5.2: SW1 DIP switch
Switch
Switch setting
Meaning
SW1-1
ON
8 data bits
SW1-2
OFF
No parity
SW1-3
OFF
No parity
SW1-4
OFF
1 stop bit
SW1-5
OFF
Must always be set to OFF
SW1-6
OFF
RS 232C
SW1-7
OFF
RS 232C
SW1-8
OFF
Must always be set to OFF
Table 5.3: Rotary encoding switch SW2
Switch setting
Meaning
0
Station number ’0’
Table 5.4: Rotary encoding switch SW3
Switch setting
Meaning
6
19200 kbit/s
Table 5.5: DIP switch SW4
Switch
Switch setting
Meaning
SW4-1
OFF
RS 422 terminating resistor not active
SW4-2
OFF
RS 422 terminating resistor not active
SW1
SW2
SW3
SW4