![Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/pepperl-fuchs/ident-m-system-v-mvi-f57-2hb12/ident-m-system-v-mvi-f57-2hb12_manual_1527667042.webp)
IDENT-M System V • TCP/IP connection
Description of commands
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Copyright Fuchs, Printed in Germany
Fuchs GmbH • 68301 Mannheim • Telefon (06 21) 7 76-11 11 • Telefax (06 21) 7 76-27-11 11 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e0
6.
09
.0
1
40
10.14 <46> Write date/time
Set the date and time of the Control Interface unit. The input is in ASCII characters.
The individual values are displayed as follows:
Year
-> 00 – 99
Month
-> 01 – 12
Day
-> 01 – 31
Weekday
-> 00 (Sun) 01 (Mon) 02 (Tue) 03 (Wed) 04 (Thu) 05 (Fri) 06 (Sat)
Hours
-> 00 – 23
Minutes
-> 00 – 59
Command:
Designation
Bit number
7
6
5
4
3
2
1
0
Byte 0
X4
X3
X2
X1
K3
K2
K1
-
Byte 1
‚4‘ (0x34)
Byte 2
‚6‘ (0x36)
Byte 3
NC
Byte 4
NC
Byte 5
NC
Byte 6
NC
Byte 7
Year
Byte 8
Year
- „ -
Month
- „ -
Month
- „ -
Day
- „ -
Day
- „ -
Weekday
- „ -
Weekday
- „ -
Hours
- „ -
Hours
- „ -
Minutes
- „ -
Minutes
- „ -
Seconds
- „ -
Seconds