PV1000agri pellet burner
p
6/ 50
Description
Specifications
DK9401A1
www.pelltech.eu
burner checks batteries condition and does not start the next working cycle if the batteries
voltage is too low.
20
Internal feeder
screw
Hollow spiral connected to feeder motor to transport pellets into burning chamber. Screw is
not tightened to motor, but has small slack. It lowers the mechanical stress and expands
gearmotor lifetime.
21
Pressure sensor
connection
Metal tube to connect pressure sensor input. Pressure sensor measures draught in burning
chamber and enables the controller to regulate flue gas fan speed.
2.2 Specifications
Parameter
Unit
PV1000agri
L
total length
mm
1300
L1
burner body length
mm
630
L2
burning chamber length
mm
690
H
total height
mm
620
H1
burner chamber height
mm
550
W
total width
mm
710
W1
burner housing width
mm
620
Mass
kg
290
Supply voltage
VAC
0
Power max
W
620
Power at standby
W
7
Noise
dB
58
Emission class
1
-
5
Operating temperature
C
o
-10…40
Nominal heat input
kW
1000
Содержание PV1000agri
Страница 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Страница 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 39: ...PV1000agri pellet burner p 38 50 Operation and maintenance Replacing components DK9401A1 www pelltech eu ...