PV1000agri pellet burner
p
21/ 50
Installation
Pellet storage
DK9401A1
www.pelltech.eu
The distance between the input of the burner and the exit tube of the auger must be at least
60cm vertically – recommended distance is 80-200cm.
Hose between auger and burner must be tight, otherwise pellets will block the auger. Falling
angle must me between 65° and 85°.
Figure 23 External auger installation
3.5 Pellet storage
Pellets must be stored in a dry and ventilated room that is separated from the boiler room. A
purpose built silo is recommended. All safety regulation must be taken into consideration
according to the local laws. It is recommended to wear a respirator when handling pellets.
Refilling must be carried out before the storage runs empty.
3.6 Electrical connections
Table 1 PV1000agri connectors
Nr.
Name
Color, type
Signals
X11
Power, thermostat
black F/ brown F
230V 3A, 230V
X12
Main Power supply
black F
3x380V 16A
X13
Safety circuit
white M
230V
X14
Pellet auger 1
black M
3x380V 0,55kW 1,6A
X15
Ash augers
white M
230V 90W
X15*
Pellet auger 2
black M
3x380V 0,55kW 1,6A
X16
Secondary fan
white M
3x230V 0,18kW 1,4A
X17
Ignitors
black M
2x500W 2,2A
X21
Fluegas fan
white M
3x230V max 1,5kW
X21*
Fluegas inverter
brown M
0...10V, 24V DC
X22
Modbus
Brown M
24V DC
X23
Pt100/4..20mA sensors
Green M
24V DC
X24*
Level sensors
Brown M
24V DC
X25*
by request
X26
Primary fan
white M
3x230V 0,18kW 1,4A
X27
Ignitors
black M
2x500W 2,2A
Содержание PV1000agri
Страница 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Страница 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 39: ...PV1000agri pellet burner p 38 50 Operation and maintenance Replacing components DK9401A1 www pelltech eu ...