PV1000agri pellet burner
p
42/ 50
Annex A – Parameters
DK9401A1
www.pelltech.eu
7 Annex A – Parameters
Par
Nr
Parameter
name
Unit
Burner
model
Default Min.
Max.
Description
Par 1 FAN @level 1
rps
PV350
24
20
30
PV500
22
15
50
PV700
28
15
50
PV1000 24
15
50
Par 2 FAN @level 3
rps
PV350
28
20
36
PV500
25
15
50
PV700
32
15
50
PV1000 30
15
50
Par 3 FAN @level 5
rps
PV350
32
20
40
PV500
32
15
50
PV700
34
15
50
PV1000 34
15
50
Par 4 FAN @level 7
rps
PV350
36
20
40
PV500
40
15
50
PV700
37
15
50
PV1000 38
15
50
Par 5 FAN @level 9
rps
PV350
42
30
50
PV500
43
15
50
PV700
40
15
50
PV1000 42
15
50
Par 6 FAN @level 11
rps
PV350
46
30
60
PV500
46
15
50
PV700
42
15
50
PV1000 45
15
55
Par 7 FAN START
%
170
80
240
Initial speed for prim., sec. and flue gas fan
to start. 0=100%, 255=0%
Par 8 FAN IGNITION
rps
20
15
35
Par 9 FAN BURN END
rps
20
10
40
Par
10
FAN HOLD
FLAME
rps
10
7
14
Par
11
HOLD FLAME
ON
min
15
5
30
Par
12
HOLD FLAME
MAX
min
60
30
90
Par
13
MIN POWER
kW
PV350
100
100/150/200/250/300/350
PV500
160
160/240/320/400/480/560
PV700
200
200/300/400/500/600/700
PV1000 250
250/400/550/700/850/1000
Par
14
MAX POWER
kW
PV350
350
100/150/200/250/300/350
PV500
560
160/240/320/400/480/560
PV700
700
200/300/400/500/600/700
PV1000 1000
250/400/550/700/850/1000
Par
15
POWER UP
min
15
5
120
Par
POWER DOWN
min
30
15
45
Содержание PV1000agri
Страница 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Страница 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 39: ...PV1000agri pellet burner p 38 50 Operation and maintenance Replacing components DK9401A1 www pelltech eu ...