PV1000agri pellet burner
p
22/ 50
Installation
Electrical connections
DK9401A1
www.pelltech.eu
* optional extras
Burner is designed to work at 230V. Boiler should be equipped with thermostat or external switch
between plug X11 pin T1 and T2 for turning on/off the pellet burner.
Internal feeder is equipped with motor thermal protection, which prevents motor from overheating. As
soon as the nominal trip temperature (TNF) of the sensor set point is exceeded, the relay detects this
variation and the output relay cuts off the power to the motor.
Burner can be equipped with optional lambda sensor. It provides efficient control for optimal
performance concentrating emissions and burning efficiency. Lambda sensor output range has linear
relationship with following points:
0 % O² -
4
25 % O² - 20
mA
mA
Figure 24 Connector markings