PV1000agri pellet burner
p
37/ 50
Operation and maintenance
Cleaning
DK9401A1
www.pelltech.eu
External auger control
4.4 Cleaning
Pellet burner requires systematic maintenance
.
The maintenance period depends on the quality of the
pellets and heating intensity.
To clean the burner:
1.
Turn off the burner by turning the thermostat to 0.
2.
Let the burner cool down for at least 1 hour.
3.
Open the boiler's door to gain access to the burning chamber
4.
Remove the grates and clean them from any residues. Make sure all holes on the grates are
clean.
5.
Remove the bottom panel to gain access under the grate movers to clean the ash from the
burning camber.
6.
Reattach the bottom panel.
7.
Clean the boiler. The frequency of cleaning the boiler depends on the type of the boiler and
heating intensity. For more information about cleaning the boiler, please see boiler's user
manual.
8.
Put back the grates.
9.
Close the boiler's door to finish the maintenance and turn the thermostat to desired
temperature.
The connection between the boiler and chimney must be completely airtight. There mustn't be any
extra draught in the smoke draft of the boiler. All cleaning and maintenance openings must be closed
with covers.
4.5 Replacing components
Step by step, how to replace igniter etc
Содержание PV1000agri
Страница 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Страница 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 39: ...PV1000agri pellet burner p 38 50 Operation and maintenance Replacing components DK9401A1 www pelltech eu ...