PV1000agri pellet burner
p
40/ 50
Optional components
Temperature sensor
DK9401A1
www.pelltech.eu
Insert the SIM and push it with the tool slightly inside until the spring snaps in. Removing the tool, the
SIM shall remain inside the GT863-PY. For removing the SIM, push the tool slightly inside until the spring
is released so that it pushes the SIM outside when the tool is retracted.
Burner´s GSM modem menu can be accessed in the PARAMETERS menu, parameter no. 52
LED indicators
The GT863-PY Terminal has 2 LED indicators, one for Power, one for Status.
Power LED
When on, the green Power LED indicates that the supply voltage is arriving at the GSM Engine
inside the GT863-PY Terminal.
Status LED
: Indication of network service availability. The red Status LED is connected internally to the
STAT_LED output of the module by an inverting circuit. In addition to the status information obtainable
via AT commands, this LED shows information on the network service availability and Call status.
Status LED
indications
5.2 Temperature sensor
Temperature sensor can be resistive PT100 type or mA output type. In
5.3 Flue gas fan
Schematics, instructions for set up.
LED status
Device Status
permanently on
a call is active
fast interrupt sequence
Net search / Not registered / turning off
(period 0,5s, Ton 1s)
slow interrupt sequence
Registered full service
(period 0,3s, Ton 3s)
permanently off
device off
Содержание PV1000agri
Страница 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Страница 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Страница 39: ...PV1000agri pellet burner p 38 50 Operation and maintenance Replacing components DK9401A1 www pelltech eu ...