![Pavone Sistemi JBX8 LCD Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/pavone-sistemi/jbx8-lcd/jbx8-lcd_technical-manual_763996028.webp)
CONSULTATION OF FISCAL MEMORY
This menu is only displayed in the case of METRIC operation.
ALIBI MEM. SUBMENU:
Message
Name
Description
Type Default
Range
Ind.Fieldbus
SEE.MEM.
See fiscal
memory
Procedure for consulting the
weighs saved in the fiscal
memory.
Spc
0 ÷
959999
In case of METRIC operation and with fiscal memory enabled:
• Each executed weigh is stored in the fiscal memory.
• For each weighing an identification code is associated (value between 0 and 959999).
• The weighing identification code is sent on the serial line at the time of weighing.
CONSULTATION PROCEDURE OF THE FISCAL MEMORY
Enter the identification code of the weighing and confirm with the PRG key.
The display shows the net weight associated with the identification code requested. Press the
PRG key to exit the procedure for consulting the fiscal memory.
If the identification code requested is not present in the fiscal memory, the timed message “NO
COD” is displayed
.
OPERATING FUNCTIONS - CELL SIMULATION
It is possible in case of a cell break to set the device to simulate the broken cell by interpolating the values
of the adjacent cells.
This procedure allows the user to use the device even if a cell breaks, waiting for it to be replaced.
OPERATING FUNCTIONS - SINGLE CELLS DISPLAY
The device can show the mV/V signal of all the cells or the relative percentages and the total in order to
easily identify problems and structural imbalances.
000000
0.000
NO COD.