I/O SETTINGS
IN/OUT SUBMENU:
Message
Name
Description
Type
Default Range
Ind.Fieldbus
FUN.IN.1
FUN.IN.2
In 1 function
In 2 function
Selection of the function
associated with input
Sel.
Zero
See table *
1401 (Fun 1)
1402 (Fun2)
MODE 1
MODE 2
Out 1 mode
Out 2 mode
Selection of the function
associated with output
Sel.
4 parameters
to be se-
lected.
See table**
See table **
HYST. 1
HYST. 2
Out 1 hyste-
resis
Out 2 hyste-
resis
Hysteresis value with
respect to the setpoint set
Com.
2
0 - Capacity
1407 (Out 1)
1414 (Out 2)
TIMER 1
TIMER2
Time of out 1
Time of out 2
Output timer. The output
is automatically disabled
after the programmed
time (in 1/10 sec.) 0 =
timing not activated
Com.
0
0 ÷ 999
1408 (Out 1)
1415 (Out 2)
DELAY1
DELAY2
Delay of out 1
Delay of out 2
Output excitation
delay with respect to
the occurrence of the
condition. (in 1/10 sec.)
Com.
0
0 ÷ 999
1409 (Out 1)
1416 (Out 2)
Function * Description
Zero [0]
It performs zero calibration.
Tare [1]
Automatic tare
Del.Tar. [2] It deletes the tare.
Peak [3]
It resets the peak function
Hold [4]
It freezes the weight captured
Send [5]
On demand data sending (if on de-
mand protocol is selected on Rs232) or
printing (if printer protocol is selected
on Rs232).
Log [6]
It activates the datalogger function
Description**
1403 OUT1—1410 OUT2 address
Net [0]/Gross [1]/Peak [2]/Sbil [3]/Alarm[4]
The threshold is compared to the net weight, gross weight
or peak. In this last case, the threshold is compared with
the last captured peak value, even when the peak function
is not ON. The Sbil selection activates the output when
the load cell reading is unbalanced.
The Alarm selection is ON when there is a problem with
the cells.
1404 OUT1—1411 OUT2 address
N.Open [0]/N. Closed [1]
Its output is normally open or normally closed.
1405 OUT1—1412 OUT2 address
Posit. [0]/Negat. [1]/All [2]
The threshold is compared only with positive weights or
only with negative weights
1406 OUT1—1413 OUT2 address
Normal [0]/Stable [1]
Its output is ON even when it is moving or only after the
weight has stabilized.