FUNCTIONAL FEATURES SETTINGS
FUNCTIONS SUBMENU
Message
Name
Description
Type Default
Range
Ind.
Fieldbus
STANDBY
Stand By
Inactivity time after which the low
brightness and keypad lock status is
automatically assumed.
0 = function OFF.
Com.
0
0 ÷ 999 sec
(Valore min.
5 sec.)
1001
LOCK
Keyboard
lock
Setting of 4 binary values
corresponding to the 4 keys.
0 -> button not locked
1-> locked button
(i.e. 0101 corresponds to block the
2nd and 4th key)
Com.
0000
0000 ÷
1111
(Binary)
1002
PIN.CODE
Password
setting
If programmed, enter the password
to access the programming menu.
In the case of subsequent accesses,
it is no longer required to enter the
password until the standby enables
or the instrument is switched off.
Com.
0
(no pas-
sword)
0 ÷ 9999
1003
LINGUA
Language
Setting
It sets the desired language
among the various ones
available
Sel.
Italiano
ITALIAN[0]
ENGLISH[1]
PEAK
Peak function
It allows you making the peak
function available or not and to
report it to the net weight or gross
weight. If the application does
not provide this function, it can be
deactivated.
Sel.
NONE
NONE [0]
NET [1]
GROSS [2]
1004
DATALOG
Datalogger *
It allows you storing the weight and
I/O status in Excel format in the
optional memory. The logging can
be of a single measurement or of a
continuous series of measurements
from the beginning of the storage
(max 1000 measurements). The
memory can hold up to 60000
records of weight, beyond which
the oldest records are overwritten.
Sel.
NONE
NONE [0]
SINGLE [1]
CONTIN.[2]
1005
LOG TRG.
Trigger for
Datalogger*
In the case of an activated
datalogger, it selects whether
the storage is done manually (by
key or input), or when output 1
or 2 is activated. Press the SET
button for a long time to start
storing from the button. Storing
can be interrupted at any time
by pressing the ZERO key.
Sel.
MANUAL MANUAL[0]
OUT1 [1]
OUT2 [2]
1006