Troubleshooting SNMP Error Messages
124
FS6300 NMS Administrator’s Reference Guide
8 • Monitoring SNMP Devices
RequestFailed: Get Response PDU received
from 192.168.1.001
Error Indication In Response: A not writable
error occurred.
ErrIndex: 1
Error occurs if the leafNode or OID that you are set-
ting the value for has no read/write access.
ErrorSending Set Request : com.pat-
ton.snmp.beans.DataException: Error: OID
not a leafnode.
Error occurs during a SET operation, if the OID
selected is not a leaf node.
Error sending set request: com.pat-
ton.snmp.beans: DataException: Error: Cre-
ating Variable
Error occurs if setting a value for a columnnode of a
table that does not have rowstatus.
LineGraphBean Error: cannot plot string
value Root.....
Error occurs when plotting a graph for a leafNode, if
the value of the selected OID is not an Integer/TimeT-
icks/ type.
LineGraphBean Error: cannot plot these val-
ues
.1.3..6.1.2.1.............................: value
................................................: value
................................................: value
Error occurs while plotting a Line/Bar Graph, if the
selected OID/LeafNode has syntax: PhysAddress,
NetworkAddress, IP Address, OBJECT IDENTIFIER.
Error: com.patton .snmp.beans.DataExcep-
tion: InvalidTable OID:(oid choosen)
Error occurs if the SNMP Table is loaded with an OID
that is not a Table OID.
ErrorSendingPDU: Failed to Authenticate the
Security Parameters, for user SnmpEngi-
neEntry not found for address( hostname)
port(portNo.)
Error occurs while creating an SNMP Table, if the
host name specified, or is a different version other
than v3 in the settings table.
LineGraphBeanError: cannot plot string
value xyz.
Error occurs if the OID/LeafNode chosen for plotting
a graph is a String type.
Discovery failed for address (hostname)
port (portno.)
Error occurs if the wrong port number is set in the
MibSettings panel.
Time Sync Failed for user (user name)
Error occurs if the wrong username/user pass-
word/priv password/ TargetHost/SecurityLevel is set
in the MibSettings panel.
Error in Getting DataBase Connection:Please
check the jdbc parameters: com.pat-
ton.snmp.beans.MibException:
java.lang.ClassNot FoundException:
Error occurs if DriverName/URL/User Name/Pass-
word has been set incorrectly when loading MIBs
from database.
Error in Getting DataBase Connection:Please
check the jdbc parameters: java.lang.Class-
NotfoundException:
(DriverName set)
Error occurs if the mysql.jar class is not present in the
classes directory.
Please enter the UserName
Error occurs if the Username is not set for the v3 User.
Table 6. SNMP Error Messages
Error Message
Description