Maintenance
82
Model 6081RC Network Access Server Getting Started Guide
10 • Troubleshooting and maintenance
4. Remove the malfunctioning Model 6081RC by pushing the handles outwards, pulling the card gently but
firmly from its slot in the chassis. Place the removed card in the container the replacement Model 6081RC
came in so you can return the defective Model 6081RC for repair.
Installing the replacement Model 6081RC
1. Insert the replacement Model 6081RC into the rack chassis.
2. Insert the rear blade into the desired slot in the rack chassis. Make sure the blade is seated properly in the
slot guides.
3. Gently press the blade into the chassis until the alignment/ESD pin engages the chassis. When the blade is
fully seated, the red buttons in the handles click up automatically, thus locking the handle and activating
the switch (closed position). The click of the button gives a visual and audible confirmation that the board
is fully seated.
4. Connect the following cables to the Model 6081RC:
– The RS-232 CONFIG cable
– The 10/100 ETHERNET cable
5. Verify that the green PWR LED is lit.
Importing a saved configuration
Before importing a saved configuration, you must define the Model 6081RC’s IP address and netmask. These
parameters are defined via the Model 6081RC RS-232 CONFIG port on the Model 6081RC.
1. Refer to
Chapter 3, “Initial configuration of the Model 6081RC”
and follow the procedures contained in
section
“Initial configuration through the RS-232 control port”
on page 31.
2. To import a saved configuration, connect your Web browser to the Administration Pages, then click on
Import/Export under the Configuration Menu to display the
Import/Export
page (
figure 55
on page 79).
3. To import a configuration file into the Model 6081RC, type the complete path and filename for the con-
figuration file you wish to load or click on the
Browse…
button to select the desired file, then click the
Submit Query
button.
Upon successfully importing the file, the Model 6081RC will display Configuration Load Complete, indi-
cating that the new operating parameters have been loaded into flash memory.
4. On the Configuration Menu, click the HOME hyperlink, then click the
Hard Reset
button under Imme-
diate Actions.
Note
Do not
select
Record Current Configuration
after importing config-
uration parameters.
Completing the installation
This section verifies that the Model 6081RC is fully operational.
1. Verify that the green PWR LED is lit. If the PWR LED is flashing green, refer to Chapter 5, “Trouble-
shooting and maintenance”.