Hardware overview
17
Model 3092 iDSL DACS Getting Started Guide
1 • Introduction
•
3-contact dry relay for external alarm systems via a 3-pin terminal block connector
System Timing and Clock Port
The iDSL Multiplexer’s system timing may be derived from the composite Clock Port, an Internal Clock from
an on-board chip, or a Network Clock from the T1/E1 WAN interface. The system timing is con-figured
through the NMS. The Clock Port features are:
•
Input for an external 64 kHz BITS (Building Integrated Timing Supply), reference clock.
•
External reference drives timing for all iDSL and WAN ports.
•
Selectable Master and Fallback Clock
Temperature
Operating range: 0–40°C (32–104°F)
Internal temperature: Available in real-time on the DACS Web management pages
Altitude
Maximum operating altitude: 15,000 feet (4,752 meters)
Humidity
5 to 90% relative humidity (RH), non-condensing
Содержание 3092
Страница 6: ...Contents Model 3092 iDSL DACS Getting Started Guide 6 ...
Страница 12: ...Model 3092 iDSL DACS Getting Started Guide 12 ...
Страница 30: ...2 Hardware installation Model 3092 iDSL DACS Getting Started Guide 30 Completing the hardware installation ...
Страница 50: ...3 Configuring the DACS for operation Model 3092 iDSL DACS Getting Started Guide 50 Completing the installation ...
Страница 55: ...Introduction 55 Model 3092 iDSL DACS Getting Started Guide 5 Troubleshooting and maintenance ...
Страница 66: ...5 Troubleshooting and maintenance Model 3092 iDSL DACS Getting Started Guide 66 Maintenance ...
Страница 71: ...71 Appendix A RJ 21X Wiring Color Chart Chapter contents Introduction 70 ...
Страница 74: ...A RJ 21X Wiring Color Chart Model 3092 iDSL DACS Getting Started Guide 74 Introduction ...