28
TQ10X User Guide
Encoder Input Connections
The TQ10X has six dedicated inputs for use with a differential incremental en-
coder. These inputs provide position information for the servo loop.
681
Ω
Internal Connections
B+
B-
681
Ω
681
Ω
Internal Connections for CHA, CHB,
and CHZ are identical
MOTOR
Encoder
3 GND
4 E5
SHIELD
5 ENCODER A+
6 ENCODER A–
7 ENCODER B+
8 ENCODER B–
Encoder Input Specifications:
• Maximum low input: 0.8V
• Minimum high input: 2.0V
• Maximum input frequency: 960 KHz
• A Leads B – CW Rotation
• B Leads A – CCW Rotation
TQ10X
Motor
+5V
200mA max. at 5V available to
power encoder electronics
9 ENCODER Z+
10 ENCODER Z–
Encoder Input
The color code for encoder wires was shown earlier for Compumotor SM and
NeoMetric Series servo motors. Connect the cable’s shield wire to the encoder
ground terminal (pin 3).
CAUTION
If you do not connect an encoder Z-channel output to the TQ10X, then you must ground the
Z+ input on the TQ10X. To do this, connect a jumper wire between the Z+ input and the
nearest available ground terminal (labeled GND).
General Purpose Inputs (IN 1 – IN 5)
The TQ10X has five general purpose inputs. Each of these inputs may be config-
ured to match the application needs. The figure represents a typical configuration
of one of these inputs.
Internal Connections
TQ10X
+5V
4.75K
Ω
HCT541
4 IN 4
8 GND
Internal Connections for IN 1 – IN 5 are Identical
• Maximum low level input: 0.8 V
• Minimum high level input: 2V
• Maximum high level input: 5V
Plant
General Purpose Input Connected to a Switch
The IN command is used to configure the inputs to the following functions:
TRIGGER INPUT – The TQ10X can dedicate up to five Trigger inputs. These
inputs are pulled up internally. These inputs are used with the Trigger (TR) com-
mand to control the TQ10X's trigger function. Minimum pulse width is 1 ms.
HOME POSITION INPUT – The TQ10X can dedicate up to one Home input.
The Home input allows you to establish a home reference position. This input is
not active during power-up. Refer to the Go Home (GH) command for more
information on setting up and using this function. Minimum pulse width is 1 ms.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание TQ10X
Страница 13: ...4 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 55: ...46 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 63: ...54 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 113: ...104 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 137: ...128 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...