➁
Installation
27
Reset Input (Optional)
You can use the reset input to reset the drive and the controller. The effect of a
reset is identical to cycling power. The reset input is internally pulled up to +5V. If
your equipment requires, you can connect the input to an external voltage as high
as +24V. You can also connect it to a dry contact closure to ground.
+5V
22K
Ω
22K
Ω
2.49K
Ω
5 RESET IN
6 RESET GND
Internal Connections
TQ10X
Normally Open
Reset Switch
Reset Input
Specifications
Maximum Applied Voltage
30 V
Maximum Current
5 mA
Active Level
Low to reset
Rotation Direction
In the following sections, we will refer to clockwise and counterclockwise direc-
tions. As the next drawing shows, shaft rotation is defined as the direction the shaft
rotates, as viewed from the mounting flange end of the motor.
Clockwise Shaft Rotation
Maximum Voltage Level on I/O Signal Inputs
CAUTION
Do not apply more than 5V maximum to inputs described in the following sections.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание TQ10X
Страница 13: ...4 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 55: ...46 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 63: ...54 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 113: ...104 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 137: ...128 TQ10X User Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...