FL20 Series
125
6.4.1 Paraemeters setting
Position pulse mode includes internal register position mode and external position mode, user can select it by Po001.
Parameters
Remarks
Po001
d □ 1
Control mode selection: position pulse mode.
d □ 5
Control mode selection: internal register position mode.
Connect power supply of servo main circuit, power supply of control circuit, motor power cable and
encoder cable correctly.
Jog trial operation by keypad.
Refer to Fig 6.4.2 and Fig 6.4.6 to connect DI/DO.
Set the related parameters of position mode.
Operating servo drive and make sure the running direction of servo motor is correct, and set related
parameters of gain adjustement, pleaser refer to Chapter 7.3.
Содержание FL20-S Series
Страница 1: ......
Страница 33: ...FL20 S Series 33 M3 structure Fig 3 1 5 Servo drive structure 3 ...
Страница 35: ...FL20 S Series 35 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5 ...
Страница 36: ...FL20 S Series 36 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6 ...
Страница 37: ...FL20 S Series 37 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7 ...
Страница 76: ...FL20 Series 76 1 2 No Name Function 1 DC 24V 2 DC 24V Plug No Name Function 1 DC 24V 2 DC 24V 3 None 1 2 3 ...
Страница 169: ...FL20 S Series 169 Fig 6 4 44FL20E Cam internal frameworkdiagram ...
Страница 347: ...FL20 S Series 347 ...