FL20-S Series
197
supply are normal, there is no servo alarms. Output OFF means that servo drive is not ready.
(3)Overload pre-alarm signal output
When servo output current reaches or exceeds overload pre-alarm current, and after overload pre-alarm
filter time, the output current still reachers or higher than pre-alarm current, then this signal is output.
Signal Name
Default terminal
Remarks
OL-W
Allocated by users
Pre-alarm signal of overload
Related parameters:
So-35
Overload pre-alarm current
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~800
%
120
Immediate effect
So-36
Overload pre-alarm filter time
speed position torque
Setting Range
Setting Unit
Mfr’s Value
Effect
0~1000
10ms
10
Immediate effect
(4)Signal output in speed limit
When rotate speed is limited, DO outputs this signal, and not related to motor rotation but valid for
forward/reverse .It should allocate 1 DO terminal(speed limiting) to servo drive and set DO terminal
logic.
Velocity V
Time t
Servo Stop
Speed limiting
OFF
ON
OFF
ON
OFF
ON
OFF
Servo Run
Speed Limit
Speed
Feedback
Fig 6.6.3 Output in speed limit under torque mode sketch map
Содержание FL20-S Series
Страница 1: ......
Страница 33: ...FL20 S Series 33 M3 structure Fig 3 1 5 Servo drive structure 3 ...
Страница 35: ...FL20 S Series 35 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5 ...
Страница 36: ...FL20 S Series 36 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6 ...
Страница 37: ...FL20 S Series 37 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7 ...
Страница 76: ...FL20 Series 76 1 2 No Name Function 1 DC 24V 2 DC 24V Plug No Name Function 1 DC 24V 2 DC 24V 3 None 1 2 3 ...
Страница 169: ...FL20 S Series 169 Fig 6 4 44FL20E Cam internal frameworkdiagram ...
Страница 347: ...FL20 S Series 347 ...