6.5.3 Analog Speed and Position Pulse Dual Mode
External analog speed and position pulse command switching mode shows the figue 6.5.2, after servo is
enabled, servo runs as position pulse mode when mode switching signal is enabled; Servo runs as analog
speed when mode switching signal is disabled.
In the running process of analog speed mode, servo slows down to zero according to deceleration time
when mode switching signal is enabled, servo cannot receive position pulse until switching to position
mode after position reach signal output is enabled.
In the running process of position pulse mode, when mode switching signal is disabled, servo switches to
analog speed mode Immediate, and run to target speed according to acceleration/deceleration time.
Speed
Curve
Position reach
output
Position pulse
input
Mode
Switching
Analog
Speed
switching
Pulse
reveiving
Analog
Speed
Fig 6.5.2 Analog speed and position pulse sequence diagram