2
1
INTENDED USE AND FEATURES
<INTENDED USE>
z
The Multiple Medical Recliner L’za is designed to be used in the treatment of dialysis patients and in
the drawing of blood samples from patients at medical institutions.
*
For details of the patient target groups, the intended users and the clinical benefits, see “
b
SPECIFICATIONS”
p. 40 and 41.
* For details of the contra-indications, see “PROHIBITED”
p. 12.
<FEATURES>
[Frequently used functions]
z
z
Adjusting the backrest angle
p. 22 and 23
• The backrest angle can be adjusted by the
handheld controller, and the patient can be
positioned in a comfortable position which is not
difficult or detrimental to the human body.
* The backrest can move from an angle of -12° to
75°.
z
z
Adjusting the leg rest angle
p. 22 and 23
• The leg rest angle can be adjusted by the
handheld controller, and the patient can be
positioned in a comfortable position which is not
difficult or detrimental to the human body.
* The leg rest can move from an angle of -30° to 12°.
z
z
Seat adjustment (3 motor type only)
p. 22 and 23
•
The height from the floor to the recliner seat face
can be adjusted by the handheld controller.
• The nurse can perform puncturing and blood
sample collection in a comfortable position.
* The seat face moves in the range of 45 cm to
76 cm.
* This operation can also be performed by the foot
control switch.
z
z
Opening and closing the armrest
p. 19
• The armrest can be opened to the outside, which
makes it easier for the patient to get on or off the
recliner.
• The nurse can perform puncturing and blood
sample collection in a comfortable position.
* The armrest can be moved to up to 45° to the
outside.
z
z
Flipping the armrest up
p. 19
•
The armrest can be flipped upward, which
enables the patient to easily be transferred from
the wheelchair.
[Other functions]
z
z
Backrest and leg rest auto contour operation
p. 24
The angle of the backrest and leg rest can be operated at the same time by the handheld controller, and the patient can thus
adjust his/her position more quickly.
z
z
Adjusting the footrest position
p. 19
The position of the footrest can be adjusted according to the height of the patient.
z
z
Adjusting the pillow position
p. 21
The position of the pillow can be adjusted according to the height of the patient.
z
z
Emergency back-lowering function
p. 30
The backrest can be lowered rapidly in case of fainting due to anemia or a similar condition and other emergency conditions,
or a power failure.
z
z
Four-wheel stopper
p. 29
A stopper is attached to each of the four wheels by which the recliner can be firmly fixed at its position.
*
The operations performed by the handheld controller, the opening/closing and flipping up of the armrest, the adjustment of
the footrest position, and the adjustment of the pillow position are intended to be used by patients.
-12° to 75°
-30° to 12°
45 cm to 76 cm