6 Options
6-12
FrameSaver NP 110 User’s Manual - Installation Guide
980-001-0240B
November
2000
8.
Ones Dens - Selects the Ones Density format to be used.
9.
Link Err Thres - Disables or sets the threshold for the DSX Threshold
Alarm. An alarm is declared when the Near End - Errored Seconds plus
Unavailable Seconds equals or exceeds the threshold in the current 15-
minute interval.
Commands
Help [?] - Advances to “Help” for CSU/Interface Configuration screen.
Save [SA] - Saves parameters and returns to System View screen.
Cancel [X] - Returns to System View screen without saving changes.
Save the DSX/Drop Configuration changes when they are all set correctly by entering
“SA” followed by ENTER. This will also return the user to the System View screen.