6 Options
6-40
FrameSaver NP 110 User’s Manual - Installation Guide
980-001-0240B
November
2000
Demand Setup - Selects the current state for demand operations.
Reset/Arm - Terminates any current activity and clears any Failed condition so
that automatic demand initiation may occur. This is the default state.
Call Out/Loop - Initiates Bandwidth On-Demand (BOD) call-out and sets a loop-
back toward the Network at the On-Demand configured data rate.
If configured for ML-PPP inverse multiplexing, the user will be prompt-
ed to enter the following items:
User Name
User Password
Network IP Address
User IP Address
After entering all the items, they will be displayed on the screen as shown
in Figure 6-20 above.
Loop to User - Loops data back toward the User at the ISDN Data Port. If a Band-
width On-Demand call is active, it will be terminated before the loopback
is established.
On-Demand Port Status - If the ISDN Adapter is not configured for
On-Demand operation, these fields will not be displayed. If
configured for On-Demand, the fields are as follows:
DTR: State of DTR lead, ON or OFF.
RTS: State of RTS lead, ON or OFF.
ISDN: Displays (blank) or the current state of the ISDN Adapter and On-De-
mand status, as reported by the ISDN Adapter module. Status states are:
ISDN Adp Fault - The ISDN hardware has failed (call cannot be
accomplished).
Primary Online - On-Demand connection in place using Primary Dial
number(s).
Secondary Online - On-Demand connection in place using Secondary
Dial number(s).
Primary DwnSpd - On-Demand connection in place using Primary Dial
number(s), but with fewer ISDN B-Channels than specified in
configuration.
Secondary DwnSpd - On-Demand connection in place using
Secondary Dials number(s), but with fewer ISDN B-Channels
than specified in configuration.
Connecting - Connection is being established.
Failed - Retry attempts exhausted.
ISDN Line Failure - The ISDN line of at least one B-Channel is faulty
(call may not be possible).
ISDN SPID Failure - An invalid or incorrect SPID has been entered for at
least one B-Channel (call may not be possible).
B1 SPID Failure - A B2-Channel cannot operate due to a SPID failure
on its associated B1-Channel.
Armed - Default state if not disabled and no failure exists.