6 Options
980-001-0240B
FrameSaver NP 110 User’s Manual - Installation Guide
6-45
November 2000
Attempt - Counted from time a bundle level action is initiated and includes the
entire operation (retries are not counted as separate attempts).
Failure - Counted only when a bundle is not established after all retries fail.
Time Since Last Attempt - A count of Days, Hours, Minutes, and Seconds
shows the time since the most recent attempt occurred for each bundle.
Commands
Reset Stats [RS] - Resets all counters but leaves the time duration values intact.
Help [?] - Advances to “Help” for ISDN Statistics screen.
Close [X] - Returns to the ISDN/Status Test screen.
AutoUpdate [AU] - Causes the status fields on the current screen displayed to refresh
automatically (approximately every five seconds).
ML-PPP
Diagnostic Trace
Feature
FrameSaver NP 110 has a built-in Diagnostic Trace feature which can be used to mon-
itor ML-PPP connection activity. This feature is equivalent to and compliments the di-
agnostic trace capabilities provided by several other major manufacturers of routers
and network switching equipment.
The Trace feature is accessed via VT-100 dial-in to the FrameSaver NP 110 ISDN
Adapter module. A dial-in call is routed to the ISDN Adapter by the unit’s integrated
call director (refer to Figure 2-10 of this manual).
The steps to activate a trace are as follows:
1. Dial-in through the unit’s modem line. The setup string must include the digits to
direct the call to the ISDN Adapter module (“w,,,4”).
2. The ISDN startup display and a password prompt will appear. Enter any character
followed by ENTER. “Login for PPP TRACE messages” should be displayed.
NOTE: If the startup display does NOT have “ISDN” in its first line, then the call
was not properly routed to the ISDN Adapter. Hang up, recheck the setup string
and place the call again.
3. Turn trace ON by entering the command, “TRACE PPPTRACE” followed by
ENTER.
4. Start diagnostic message display by entering the command, “DIAG” followed by
ENTER.
The first line will display, “Entering Diagnostic Mode - Press “Esc” To go back to
OCP Mode.” Thereafter, each event message will be displayed as it occurs.
The Trace Diagnostic Mode will remain active until the user presses the Esc key or an
inactivity logout occurs (5 minutes without keystroke.)
Содержание FrameSaver NP 110
Страница 17: ...1 Preface 1 6 FrameSaver NP 110 User s Manual Installation Guide 980 001 0240B November 2000 ...
Страница 107: ...5 Diagnostics 5 40 NetPath 110 User s Manual Installation Guide 980 001 0240B November 2000 ...
Страница 175: ...Appendix A 18 FrameSaver NP 110 User s Manual Installation Guide 980 001 0240B November 2000 ...