Appendix
980-001-0240B
FrameSaver NP 110 User’s Manual - Installation Guide
A-13
November
2000
V54 User Lp to Netw
Loopback is in place at the User Port toward the Network Circuit, in response to a
V.54 LoopUp code from the Network (only if DS0s are assigned to the User Port.)
Line Lp to DSX
Full T1 Line Loopback in place toward the DSX Circuit.
Payld Lp to DSX
Full T1 Payload loopback in place toward the DSX Circuit.
QRSS to DSX
Full T1 QRSS pattern BERT is being sent toward the DSX Circuit.
DSX 2047 to Netw
2047 pattern BERT is being sent toward the Network Circuit (for DS0s assigned to
DSX Port @ Nx56K.)
DSX Zero to Netw
All Zeros pattern BERT is being sent toward the Network Circuit (for DS0s assigned
to DSX Port @ Nx56K.)
2047 to DSX
2047 pattern BERT is being sent toward the DSX Circuit (for DS0s assigned to DSX
Port @ Nx56K.)
DSX Lp to Netw
Loopback is in place at the DSX Port (for DS0s assigned to DSX Port @ Nx64K)
toward the Network Circuit.
DSX CFA/Red Alarm
Detected loss of DSX Circuit Facility. Framing must be enabled for DSX.
DSX Rmt/Yellow Alarm
Carrier alarm notification that Transmit failure from this DCE has been detected on
this DSX Circuit Facility. Framing must be enabled for DSX.
DSX AIS/Blue Alarm
Carrier alarm notification that an upstream signal failure has been detected on this
DSX Circuit Facility. Framing must be enabled for DSX.
Lp to Drop
Loopback is in place at the Drop Port toward the Drop Circuit.
Drop Lp to Netw
Loopback is in place at the Drop Port toward the Network Circuit.
Drop 2047 to Netw
2047 pattern BERT is being sent toward the Network Circuit (for DS0s assigned to
Drop Port).
Drop Zero to Netw
All Zeros pattern BERT is being sent toward the Network Circuit (for DS0s assigned
to Drop Port).
2047 to Drop
2047 pattern BERT is being sent toward the Drop Circuit.
V54 Drop Lp to Netw
Loopback is in place at the Drop Port toward the Network Circuit, in response to a
V.54 LoopUp code from the Network (only if DS0s are assigned to the Drop Port.)
LL to Drop
Loopback is in place at the Drop Port toward the Drop Circuit, in response to an LL
(Local Loopback) signal at the Drop Port interface (only if DS0s are assigned to the
Drop Port.)
Single Flash Fail
Failure of one of the unit’s two Flash Memory modules detected by the unit.
SEEPROM Failure
Failure of SEEPROM hardware detected by the unit.
Netw Threshold Alarm
Network Link Error Threshold (Data Frame Error Seconds) reached or exceeded.
DS0s must be assigned to the User Port.
User Threshold Alarm
User Link Error Threshold (Data Frame Error Seconds) reached or exceeded. DS0s
must be assigned to the User Port.
Table A-13 System Test/Fault
Display
Description