Test/BKP
(DSX)
Test/BKP shows the highest priority CSU or DSX related test or Backup (ISDN) con-
dition currently detected. This is displayed on the CSU/DSX Statistics Summary
screen when in DSX Mode.
Table A-15 Test/BKP (DSX)
Display
Description
Mgmt Line Netw
Operator initiated Full T1 Line loopback in place at Network Port toward Network
Circuit.
Mgmt Pyld Netw
Operator initiated Full T1 Payload loopback in place toward Network Circuit.
Mgmt QRSS Netw
Operator initiated QRSS pattern BERT is being sent toward the Network Circuit.
Mgmt Alt1 Netw
Operator initiated Alternating Ones pattern BERT is being sent toward the Network
Circuit.
Mgmt 2047 Netw
Operator initiated 2047 pattern BERT is being sent toward the Network Circuit.
Mgmt Zero Netw
Operator initiated All Zeros pattern BERT is being sent toward the Network Circuit.
Mgmt Loop Cpe
Operator initiated Full T1 Line Loopback applied within the unit’s framer toward the
CPE port(s): User Port (also DSX Port and Drop Port if DSX/Drop Adapter installed.)
Mgmt Send Lp Up
Operator initiated T1 Line Loop Up code sent toward the Network.
Mgmt Send Lp Dn
Operator initiated T1 Line Loop Down code sent toward the Network.
Netw Set Line
Externally initiated (Network sent code) Full T1 Line loopback in place at Network
Port toward Network Circuit.
Netw Set Payld
Externally initiated (Network sent code) Full T1 Payload loopback in place toward
Network Circuit.
Dsx Loop Netw
Operator initiated Loopback is in place at the DSX Port (for DS0s assigned to DSX
Port @ Nx64K) toward the Network Circuit.
Dsx 2047 Netw
Operator initiated 2047 pattern BERT is being sent toward the Network Circuit (for
DS0s assigned to DSX Port @ Nx56K.)
Dsx Zero Netw
Operator initiated All Zeros pattern BERT is being sent toward the Network Circuit
(for DS0s assigned to DSX Port @ Nx56K.)
Dsx Line Dsx
Operator initiated Full T1 Line Loopback in place toward the DSX Circuit.
Dsx Pyld Dsx
Operator initiated Full T1 Payload loopback in place toward the DSX Circuit.
Dsx QRSS Dsx
Operator initiated Full T1 QRSS pattern BERT is being sent toward the DSX Circuit.
Dsx 2047 Dsx
Operator initiated 2047 pattern BERT is being sent toward the DSX Circuit.