5 Diagnostics
5-20
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
PVC Statistics
History
The PVC Statistics History screen displays all performance parameters for the Frame
Relay Traffic on a per-PVC and per-interval basis for each of the 96 possible intervals.
The first history screen is accessed by selecting ViewHistory [VH] from the PVC Sta-
tistics Summary screen.
The first page of the PVC History screen is shown in Figure 5-14.
The first page begins with Interval # 1.
Figure 5-14 PVC Statistics History Screen
Mode [M=] - Selects one of the displayed modes (refer to the PVC Statistics
Summary Screens for detailed descriptions). Display fields will correspond to the
mode selected.
First DLCI - Defines the lowest number DLCI to be displayed on the screen.
First Interval [F=#] - Selects the first interval number of the possible 96, to begin the
display of data. The data lines (16 lines per screen) will be filled by as many subse-
quent intervals as can fit without placing only part of their DLCIs on the screen. The
selection defaults to 1 when first entering the History screen.
**************************** PVC Statistics History ****************************
Name: F@43802 Mode[M=P,O,TC,RC,TL,RL,FD,orND]:Pkt
FirstDLCI[L=#]:16 (Pkt,Oct,TxCir,RxCir,TxLoss,RxLoss,FullDlay,orNetwDlay)
Past FirstInterval[F=#]: 2 of 96 DLCI[D=#,All,orSum]:All Delay(mS)
Int. DLCI RxPkts TxPkts BECN FECN RxDE TxDE Avg Max
2 25 0 0 0 0 0 0 55 70
234 0 0 0 0 0 0 55 70
3 25 0 0 0 0 0 0 55 70
33 0 0 0 0 0 0 55 70
234 0 0 0 0 0 0 55 70
4 25 0 0 0 0 0 0 55 70
33 0 0 0 0 0 0 55 70
234 0 0 0 0 0 0 55 70
5 25 0 0 0 0 0 0 55 70
33 0 0 0 0 0 0 55 70
234 0 0 0 0 0 0 55 70
6 25 0 0 0 0 0 0 55 70
33 0 0 0 0 0 0 55 70
234 0 0 0 0 0 0 55 70
Help[?] Close[X] Ne]
>