Alarms
NetPath 100 generates “traps” (SNMP alarms or alerts) in response to certain detected
network conditions. The traps are reported either In-band utilizing the Management
PVC, or via Dial-Out utilizing the internal Modem. Alarm conditions are also dis-
played on NetPath 100 status screens and on front panel indicators.
Traps
The conditions (objects) which generate traps are included in the NetPath 100 Private
MIB Extension and are listed in Table 5-2.
Table 5-2 Traps - Private MIB Extension
Component
Object
Description
Trap
Reported
In-Band/
Modem
T1 Facility
Carrier Loss
(Red, Blue or Yellow)
Carrier status of T1 facility.
Modem* &
In-Band
Total Secs in error
(ES + UAS)
Errored seconds based on the current interval performance.
In-Band
CSU
CSU Fault
Unit subsystem failed self-test.
Modem* &
In-Band
LMI
LMI Netw Failure
Errored LMI response per N392/393 counters on Network side.
Modem* &
In-Band
LMI User Failure
Errored LMI enquiries per N392/393 counters on User side.
In-Band
Link Data
Network Frame Errors
Secs
Errored seconds based on the current interval performance.
In-Band
User Frame
Errors Secs
Errored seconds based on the current interval performance.
In-Band
BECN/FECN
Secs (max PVC)
Highest BECN/FECN seconds of all PVCs based on the current interval
performance.
In-Band
PVC Dropped Monitor
Packets
Highest Dropped packet count of all PVCs based on the current interval
performance.
In-Band
PVC Delay
msec (max PVC)
Highest PVC round trip delay of all PVCs based on the current interval
performance.
In-Band
PVC Delivered Packets
(%) (
Lowest percentage of Delivered packets of all PVCs based on current interval
performance.
In-Band
PVC Available
PVC going from non-Active to Active as reported by frame switch.
In-Band
PVC Unavailable
PVC going from Active to non-Active as reported by frame switch.
In-Band
DTE
DTR Loss
Returns state of DTR lead.
In-Band
DTE Power Loss
Returns state of DTE Power indication.
In-Band
Power
NetPath Power Loss
State of AC power into unit. Reports on loss only. Sent to first trap manager
only.
In-Band
Modem
Modem Failure
Modem failed self-test which is initiated periodically.
In-Band
Dial Line Failure
Dial line failed self-test which is initiated periodically.
In-Band
Security
Security Violation
(Login)
Identifies access point of failed login attempts
(3 consecutive): Console, Modem, Telnet, UDP, or SNMP.
In-Band
Authentication Failure
Unauthorized SNMP Community Access detected (community not
configured for access).
In-Band
Aux Functions
External Alarm
Sensed contact closure.
In-Band
* Modem-Reported Traps are only issued on the occurrence of a primary facility failure and provided that the modem is not
already in use when the trap occurs.