5 Diagnostics
5-4
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
Device
Status / Test
The Device Status / Test screen provides base module status and access to system tests.
The Device Status / Test screen is shown in Figure 5-2.
Figure 5-3 Device Status / Test Screen
CSU Fault, Netw Set Loop, Frame Mgr Fault - Display (blank) or the highest prior-
ity Fault or Network Loop causing a disruption of the data path.
Refer to the Appendix in this manual for a list and description of fault and loop
displays.
Test Mode - Allows selection of the following mutually exclusive test modes:
Clear - Terminates operator or Telco-initiated Loopbacks, BERT,
and Test Packet tests.
Line Lp to Netw - Sets a Line Loopback at the T1 interface toward the Network.
Payld Lp to Netw - Sets a Payload Loopback in the CSU toward the Network.
Send LoopUp - Sends a T1 Line Loopback code toward the Network.
Send LoopDn - Sends a T1 Remove Line Loopback code toward the Network.
***************************** Device Status / Test *****************************
Name: F@43802
CSU Fault: T1 ID: NONAME
Netw Set Loop:
Test Mode [T=]
1) Clear Frame Mgr Fault: LMI Netw Failure
2) Line Lp to Netw
3) Payld Lp to Netw High Speed Interface
4) Send LoopUp DTR: On
5) Send LoopDn RTS: On
>>6) QRSS to Netw<< Power: On
7) Alt Ones to Netw Interface: ITU-V35
8) 2047 Payld to Netw
9) 2047 Payld to User
10) Loop to User
11) Test Pkts to Netw
BERT: Blocks Sent: , , Block Errors: , , BlkErr Rate: 0.00E+00
Test Duration: 00:00:00
ResetTest[RT] InjectErr[IE secs] RebootExt[RE secs]
Help[?] Close[X] AutoUpdate[AU]
>