3 Installation
980-001-0210K
NetPath 100 User’s Manual - Installation Guide
3-5
November 2000
NetPath 100 with ISDN
a. The POWER LED will light immediately and stay on.
b. The READY and ISDN READY LEDs will flash while the unit per-
forms its self-test (test duration - approximately 45 seconds).
c. The READY and ISDN READY LEDs will be ON steady after suc-
cessful completion of the self-test.
d. The T1 ALARM and FR MGMT. LEDs should not be flashing
together.
e. All other LED indications should be ignored at this time.
If the LED indications are not as described above, refer to section 5 Diagnostics of this
manual.
If operation looks normal, unplug the NetPath 100 and make the required data input/
output connections. If an optional Power Control Unit is to be installed with this Net-
Path 100, proceed to the next page of this manual. Otherwise, skip this page and go the
Input/Output Connections section.
NOTE: The NetPath 100 does not have a Power ON/OFF switch. To remove power
from the NetPath 100, disconnect the Power Cord from the AC outlet.
CAUTION
It is recommended that you remove AC power from the
NetPath 100 before attaching input and output cables
during the installation process.