5 Diagnostics
5-10
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
Frame Manager
Statistics
Summary
The Frame Manager Statistics Summary screen provides summary performance infor-
mation and access to detailed performance history displays for general Frame Relay
Traffic.
The Frame Manager Statistics Summary screen is accessed from the System View
screen, selecting [FS] by typing “FS” followed by ENTER.
The Frame Manager Statistics Summary screen is shown in Figure 5-7.
Figure 5-7 Frame Manager Statistics Summary Screen
System Test / Fault: Displays (blank) or the highest priority Test or Fault causing dis-
ruption of the data path.
Refer to the Appendix in this manual for a list and description of all fault
displays.
High Speed Interface Status -
DTR:State of DTR lead, when Power is being detected from the DTE.
States are: ON, OFF or (blank) if Power OFF.
RTS:State of RTS lead, when Power is being detected from the DTE.
States are: ON, OFF or (blank) if Power OFF.
Power: ON or OFF based on sensing voltage on Tx data lead(s) from the DTE
Current Interval Count: - Displays the number of seconds that have elapsed
in the current 15-minute interval.
24Hr Interval Count: - Displays the number of 15-minute intervals that have been ac-
cumulated since the last reset of the counters (max. of 96).
*********************** Frame Manager Statistics Summary ***********************
Name: F@43802
System High Speed Interface Status
Test/Fault: DTR: On
RTS: On
Power: On
Current Interval Count: 455 secs
24 Hour Interval Count: 96 Valid
---- Network ---- ----- User ------
LTO LFE DFES LTO LFE DFES
Current 0 0 0 0 0 0
24 Hour 0 0 0 0 0 0
ResetStats[RS] ViewHistory[VH current_time(optional)]
Help[?] Close[X] AutoUpdate[AU]
>