3800 Series S-Registers
S-Register
Front Panel Branch
Description
S55
Access From Remote
Register determines if a modem’s DCP can be accessed by a remote
modem.
Register has the following values:
0 = Enable
1 = Disable
Factory setting is Enable.
Configure\Edit\Misc
S56
Remote Access Password
Register allows entry of the first pair (leftmost) of digits of a remote
access password. Any value from 00 to 99 is valid. For example, if the
remote access password is 12345678, then S56 = 1 and 2.
Configure\Edit\Misc
S57
Remote Access Password
Register allows entry of the second pair of digits of a remote access
password. Any value from 00 to 99 is valid.
Configure\Edit\Misc
S58
Remote Access Password
Register allows entry of the third pair of digits of a remote access
password. Any value from 00 to 99 is valid.
Configure\Edit\Misc
S59
Remote Access Password
Register allows entry of the fourth pair (rightmost) of digits of a remote
access password. Any value from 00 to 99 is valid.
Configure\Edit\Misc
S61
CT111 Rate Control
Register determines if CT111 Rate is disabled, set for Fallback 1 or
Fallback 2. CT111 Rate allows the DTE to control modem rate via Pin 23
of the EIA-232-D interface. This configuration option determines the
effect of the DTE Rate Control signal. It is only valid in Async Direct
mode and Synchronous mode. For proper operation, disable the V32bis
Autorate and V32bis Automode configuration options.
Register has the following values:
0 = Disable
1 = Fallback 1
2 = Fallback 2
Factory setting is Disable.
Configure\Edit\DTE
Interface
S62
V.25bis Coding
Register identifies to the modem the type of coding used by the DTE
while in V.25bis mode.
Register has the following values:
0 = ASCII
1 = EBCDIC
Factory setting is ASCII.
Configure\Edit\DTE Dialer
S63
V.25bis Idle Character
Register identifies to the modem the type of idle fill used by the DTE
while in V.25bis mode.
Register has the following values:
0 = Mark
1 = Flag
Factory setting is Mark.
Configure\Edit\DTE Dialer
Содержание COMSPHERE 3800 Series
Страница 1: ...COMSPHERE 3800 SERIES MODEMS MODELS 3810 3811 AND 3820 USER S GUIDE Document No 3810 A2 GB30 30 ...
Страница 9: ...COMSPHERE 3800 Series Modems G September 1998 3810 A2 GB30 30 ...
Страница 15: ...COMSPHERE 3800 Series Modems vi September 1998 3810 A2 GB30 30 ...
Страница 47: ...COMSPHERE 3800 Series Modems 4 16 September 1998 3810 A2 GB30 30 ...
Страница 61: ...COMSPHERE 3800 Series Modems 7 6 September 1998 3810 A2 GB30 30 ...
Страница 69: ...COMSPHERE 3800 Series Modems 8 8 September 1998 3810 A2 GB30 30 ...
Страница 125: ...COMSPHERE 3800 Series Modems 11 4 September 1998 3810 A2 GB30 30 ...
Страница 195: ...COMSPHERE 3800 Series Modems H 2 September 1998 3810 A2 GB30 30 ...
Страница 205: ...COMSPHERE 3800 Series Modems Glossary 10 September 1998 3810 A2 GB30 30 ...
Страница 212: ...00282600 See page 12 10 Set Admin PsWd ...
Страница 213: ... 3810 A2 GB30 30 3810 A2 GB30 30 ...