AT Commands and S-Registers
B-17
Issue 1 April 1994
Table B-1. AT Command and S-Register List (16 of 34)
AT
Command/
S-Register
Description
S84=
n
AT Command Mode
Determines how the DataPort 2001 responds to
valid and invalid AT commands.
S84=0
Normal
S84=1
ERROR result code is not issued in
response to invalid commands
S84=2
All invalid commands and all commands
that alter configuration options are
ignored
CAUTION: Once the ATS84=2 command has
been issued, the DataPort 2001 cannot be
reconfigured by any AT commands, and it
responds OK to all commands. Commands that
do not affect configuration function normally. The
only configuration change that is acted on is
ATS84=0, which restores normal AT Command
mode.
S85=
n
Fast Disconnect
Determines whether the DataPort 2001 instantly
goes on-hook in response to a disconnect
command.
0 = Disable
1 = Enable