RF Module Supervision Timer Settings
Section
[706]
: Supervision Options
Option
[1]
OFF= Check-in supervision interval is every 24 hours (default)
Option
[1]
ON= Check-in supervision interval is every 80 minutes
Option
[1]
defines the time period that the control panel will expect a check-in status signal from its assigned wireless transmitters. For example, if the timer is set to
80 minutes (option
[1]
= ON), the control panel will expect a check-in status signal to be sent from its assigned wireless transmitters within 80 minutes. If the control
panel does not receive a signal from one of its wireless transmitters within the period of time defined here, it can then generate a trouble, an alarm, and/or can
transmit a report code to the monitoring station (See “Supervision Options” on page 36).
RF Jamming Supervision
Section
[700]
: Zone Options
Option
[5]
OFF= RF Jamming Supervision Disabled
Option
[5]
ON= RF Jamming Supervision Enabled (default)
With option [5] ON, a trouble will be generated when the panel’s RF signal is jammed or encounters interference for a minimum of 10 seconds.
Wireless Serial Number Display
Section
[960]
: Find Wireless Serial Number Display
To see the wireless serial number display, enter section
[960]
. Press the anti-tamper switch of the desired module to be viewed. The first digit of the serial number
will illuminate on the keypad. Press
[
ENTER
]
to see each consecutive digit. Press
[
CLEAR
]
to exit.
Remote Control Programming
The control panel accepts up to thirty-two fully programmable remote controls. Programming the remote controls is accomplished in two steps:
1.
Assign the remote controls to the control panel.
2.
Program the buttons on the remote controls.
Assigning a Remote Control to the Control Panel
Sections
[651]
to
[682]
: Remote Controls 1 to 32 respectively
Remote controls are assigned to the panel using the Automatic Learning method via the Master Quick Menu Programming or by entering the serial number.
Deleting Assigned Remote Controls
Sections
[651]
to
[682]
: Remote Controls 1 to 32 respectively
Remote controls can be deleted by deleting the corresponding user (see the Quick Menu in the user guide).
How Do I Assign a Remote Control to the Control Panel?
1.
Press the
[
ENTER
]
key.
2.
Enter your
[
INSTALLER
CODE
]
(default: 0000 / 000000) or
[
MAINTENANCE
CODE
]
(empty by default)
3.
Enter the desired
[
SECTION
NUMBER
]
(from sections
[651]
to
[682]
).
4.
Enter the six-digit serial number of the remote.
How Do I Delete a Remote Control?
1.
Press the
[
ENTER
]
key.
2.
Enter your
[
INSTALLER
CODE
]
(default: 0000 / 000000) or
[
MAINTENANCE
CODE
]
(empty by default)
3.
Enter the desired
[
SECTION
NUMBER
]
(from sections
[651]
to [
682]
).
4.
Press the
[0]
button six times to delete the serial number.