Magellan & Spectra SP • Installation Guide
31
Delayed Fire Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
12
When a Delayed 24Hr. Fire zone opens, whether it is armed or disarmed, the control panel will react as
shown in Figure 10. Delayed 24Hr. Fire zones are commonly used in residential homes where a smoke
detector often generates false alarms (i.e., burning bread, etc.). Fire alarms generate an intermittent
(pulsed) bell/siren output signal as shown in Figure 9 above.
Instant Fire Silent Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
13
When a Instant Fire Silent zone opens, whether it is armed or disarmed, the control panel will generate
the following:
The control panel can send the corresponding Alarm Report Code and the alarm will be silent
regardless of other settings.
Delayed Fire Silent Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
14
When a Delayed Fire zone opens, whether it is armed or disarmed, the control panel will react as
shown in Figure 10. Delayed 24Hr. Fire zones are commonly used in residential homes where a smoke
detector often generates false alarms (i.e., burning bread, etc.). The control panel can send the
corresponding Alarm Report Code and the alarm will be silent regardless of other settings.
24 Hr. Buzzer Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
15
When a 24Hr Buzzer Zone opens, whether the zone is armed or disarmed, the control panel sets off
the keypad’s buzzers to indicate that the zone was breached. The control panel will report the alarm,
but will not enable the bell/siren output. Enter any valid access code on the keypad to stop the buzzer.
This zone definition is particularly useful when a user wishes to be notified when something such as a
safe or locker within the home has been accessed (i.e. a child accessing a valuable collection).
24 Hr. Burglary Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
16
when a 24Hr Burglary Zone opens, whether the system is armed or disarmed, the control panel will
immediately generate an alarm. This alarm is defined by the alarm type, configured in Zone
Programming under zone options
[4]
and
[5]
. See
24 Hr. Hold-up Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
17
When a 24Hr. Hold-up zone opens, whether it is armed or disarmed, the control panel will immediately generate an alarm. This alarm is defined by the alarm type,
configured in Zone Programming under zone options
[4]
and
[5]
on page 33. The SIA FSK and CID reporting formats include specific report codes
to identify the alarm as a Hold-up alarm.
24 Hr. Gas Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
18
When a 24Hr. Gas zone opens, whether it is armed or disarmed, the control panel will immediately generate an alarm. This alarm is defined by the alarm type,
configured in Zone Programming under zone options
[4]
and
[5]
on page 33. The SIA FSK and CID reporting formats include specific report codes
to identify the alarm as a Gas alarm.
24 Hr. Heat Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
19
When a 24Hr. Heat zone opens, whether it is armed or disarmed, the control panel will immediately generate an alarm. This alarm is defined by the alarm type,
configured in Zone Programming under zone options
[4]
and
[5]
on page 33. The SIA FSK and CID reporting formats include specific report codes
to identify the alarm as a Heat alarm.
24 Hr. Water Zones
Sections
[001]
to
[032]
: Zones 1 to 32, First Digits =
20
When a 24Hr. Water zone opens, whether it is armed or disarmed, the control panel will immediately generate an alarm. This alarm is defined by the alarm type,
configured in Zone Programming under zone options
[4]
and
[5]
on page 33. The SIA FSK and CID reporting formats include specific report codes
to identify the alarm as a Water alarm.