10
Magellan & Spectra SP • Installation Guide
MG5075 PCB Layout
To provide maximum
lightning protection we
strongly recommend having
separate earth connections
for the dialer and zone
ground terminals.
Max. number of keypads: 15 keypads
Max. aux. current: 2.5A
Max. distance of bus module from panel: 76 m (250 ft.)
Max. total run of wire: 230 m (750 ft.)
This equipment must be installed and maintained by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the MGSP Reference & Installation Manual.
The sum of the current drawn from the
BELL
and
AUX
must be limited to 4A. Exceeding this limit will overload the panel power supply and
lead to complete system shutdown.
Disconnect
telephone line
before servicing.
1 PGM Trigger: This jumper allows you to choose whether the solid state
relay PGMs are ground (-), or give out 12V (+)
2 Four-pin connector can be used for quick installation of a keypad
3 EBUS (J3) and Dialer (J4) used with:
•
VDMP3 Plug-in Voice Module for voice reporting
•
PCS Series GSM Communicator Module
4
LEDs
AC LED:
•
ON = No AC power failure trouble; OFF = AC power failure trouble
Battery LED:
•
ON = Battery is ON or charging; OFF No battery or no DC IN
Bus LED:
•
Flash once every second: Normal
•
Flashes ON 1 sec. and OFF 1 sec.: Any trouble
•
Always ON: Panel is using phone line
•
Fast flash 6 seconds after power-up: Installer lock enabled
AUX LED:
•
ON = power on Aux; OFF = No power
RF-RX / RF-TX LED:
•
FLASH / OFF = Receive valid message
•
OFF / FLASH = Transmit RF message
•
FLASH / FLASH = RF firmware upgrade
5 Antenna
6 Serial: Used for connecting the IP Internet Module/PCS (Data); also used
for In-Field Firmware upgrade through a 307USB Direct Connect
Interface
7 Panel Reset
8 Zone Input
9 PGM Output, PGM Output, PGM trigger: this jumper allows you to
choose whether the solid state relay PGMs are grounded (-), or give out
(12V (+).
10 Backup Battery connections
11 Int. Power Supply (75W): 110-220 Vac, 50-60 Hz / Wall Plug (60W) 15Vdc
12 The
BELL
output will shutdown if the current exceeds 3A
13 AWG #14 single conductor solid copper wire
14 Ground clamp
15 Cold water pipe grounding
16 To ground
17 Keypad zone configuration
18 Zone connection, if EOL is enabled, see section
[706]
option 2,
on
page page 34
19 To connect additional wiring to auxiliary power, use the red (
+
) and black
(
-
) keypad connectors; auxiliary power will shut down if current exceeds
3A; if the auxiliary output is overloaded and shuts down, you must
disconnect all loads from the output for at least 10 sec. before
reconnecting any load back to the auxiliary output
Do not cut, bend, or alter
the antenna, and ensure
that electrical wires do not
cross over it, as this may
affect signal reception.