Magellan & Spectra SP • Installation Guide
45
Restrict Arming on Wireless Supervision Trouble
Section
[703]
: Arming/Disarming Options
Option
[7]
OFF= Permit arming on wireless supervision failure (default)
Option
[7]
ON= Restrict arming on wireless supervision failure
If this option is enabled, the control panel will not arm the system if the control panel detects a wireless supervision trouble on one or more zones. The control panel
will not arm the system until all wireless supervision trouble conditions are rectified.
WARNING: This feature will not function if the tamper recognition options (See “Tamper Recognition” on page 47) are disabled or whenever the
tampered zone is bypassed and the tamper bypass options have been enabled (See “Tamper Bypass Options” on page 47).
Arm/Disarm with VDMP3
Section
[703]
: Arming/Disarming Options
Option
[8]
OFF= Arm/Disarm with VDMP3 disabled
Option
[8]
ON= Arm/Disarm with VDMP3 enabled (default)
If this option is enabled, arming/disarming with the VDMP3 is functional. Disable the option if you do not want the ability to arm/disarm the system via telephone.
Timed Auto-Arming
Section
[741]
= Partition 1,
[742]
= Partition 2
Option
[1]
OFF= Timed Auto-Arming Disabled (default)
Option
[1]
ON= Timed Auto-Arming Enabled
Each partition can be programmed to arm every day at the time specified by the Auto-arm Timer. The auto-arming options (See “Auto-Arming Options” on page 45)
determine the partition's arming method. Any open zones detected when a partition is auto-armed will be bypassed regardless of their definition (except 24Hr
zones). The control panel will enter a 60-second exit delay period before arming the system. At this point, auto-arming can be cancelled by entering a valid access
code. Once the partition has successfully armed, the control panel can transmit the Timed Auto-arming report code programmed in section
[860]
.
Example:
To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-arming for partition 2 by turning on option
[1]
in section
[742]
. Then key in 18:15 into
section
[762]
.
Auto-Arm Timer
Section
[761]
= Partition 1,
[762]
= Partition 2
Select the section corresponding to the desired partition and program the time (use the 24-hour clock i.e. 6:30PM = 18:30) that you wish the control panel to
attempt to arm the selected partition and/or send the Late to Close report code.
No Movement Auto-Arming
Section
[741]
= Partition 1,
[742]
= Partition 2
Option
[2]
OFF= No Movement Auto-Arming Disabled (default)
Option
[2]
ON= No Movement Auto-Arming Enabled
If no movement occurs in a partition's protected area for the period specified by the No Movement Timer, the control panel can automatically arm that partition.
The Auto-arming Option determines the partition's arming method. Any open zones detected when a partition is Auto-armed will be bypassed regardless of their
definition (except 24Hr zones). Upon arming, the control panel will transmit the No Movement report code if programmed in section
[860]
. Regardless of whether
the system was successfully armed or not, the control panel will always transmit the No Movement report code if programmed in section
[860]
. If No Movement
Auto-arming is disabled, the control panel will still send the No Movement report code at the time specified by the No Movement Timer.
Example:
To arm partition 1 whenever there is no movement for a period of 4 hours, enable No Movement Auto-arming for partition 1 by turning on the
[2]
Option in
section
[741]
. Then in section
[749]
enter 016 (16x15min = 240min = 4 hours).
No Movement Timer
Section
[749]
= Partition 1,
[750]
= Partition 2
000 to 255 x 15 min, Default = Disabled
Select the section corresponding to the desired partition and program the interval of time without movement you wish the control panel to wait before arming
and/or sending the No Movement report code. If No Movement Auto-arming is disabled, the control panel can still send the No Movement report code when no
movement has been detected for the period specified by the No Movement Timer.
Auto-Arming Options
(Not to be used with UL installations)
Section
[741]
= Partition 1,
[742]
= Partition 2
When using Timed Auto-arming or No Movement Auto-arming, the control panel can Regular, Sleep or Stay arm the selected partition.
[3]
[4]
OFF
OFF
Regular
OFF
ON
Sleep
ON
OFF
Stay